ZU HOW INDUSTRY CO., LTD
Products
Specification
Specification
Type | AK-40 | AK-60 | AK-40H | AK-60H | ||
---|---|---|---|---|---|---|
Heat Output | kcal/h | 40000 | 60000 | 40000 | 60000 | |
kw/h | 46 | 69 | 46 | 69 | ||
Max. Working Temp. | ℃ | 80 | 80 | 150 | 150 | |
Efficiency | % | 92 | 92 | 88 | 88 | |
Gas | 13A | Nm3/h | 4.3 | 6.4 | 4.6 | 6.9 |
LPG | kg/h | 3.8 | 5.5 | 4 | 5.9 | |
Diesel | 5.1 | 7.5 | 5.4 | 8.1 | ||
GAS | 13A | mm | 15 | 15 | 15 | 15 |
LPG | 15 | 15 | 15 | 15 | ||
Diesel | 10 | 10 | 10 | 10 | ||
Control Method | - | Automatic | Automatic | Automatic | Automatic | |
Burner Motor | HP | 1/4 | 1/4 | 1/4 | 1/4 | |
HP | 1 | 2 | 1/2 | 1 | ||
Chimney Dia | mm | 150 | 150 | 150 | 150 | |
360*3 | 360*3 | 360*1 | 360*1 | |||
Power Wire Intel Dia | 2.0 | 2.0 | 2.0 | 2.0 | ||
Product Weight | kg | 340 | 350 | 400 | 410 | |
Dimensions | Lenth | mm | 1620 | 1620 | 1720 | 1720 |
Width | 862 | 862 | 962 | 962 | ||
Height | 1672 | 1672 | 1772 | 1772 |
NOTES: | |
1. | AK- x x x x K indicates diesel air heating furnace. |
2. | Standard power is 3ph/220v/60hz. Notice of change, if any, is required. |
3. | Fuel consumption is calculated at low heat value:diesel 8400kcal/l. |
4. | Partial modification for improvement is allowed without notice. |
5. | The error allow value of boiler efficiency is ±1%. |