Products
Applications:
The ultra thin wall heat shrinkable tubing is thinner than the general purpose G5 tubing. In addition to the same application as G5, its ultra thin wall thickness has lower shrink temperature and faster shrinkage speed. It is used for the connector protection in the high density space and reduces the damage to temperature-sensitive components when heating.
Approvals / Specifications:
UL224 File no. E255532, 125℃ VW-1 300V
Operating temperature range:
Continuous operating temperature: -55℃ ~ 125℃
Minimum shrink temperature: 60℃
Full recovery temperature: Above 110˚C
Color:
black
Standard color :Black (special size, cut pieces are available on request.)
Characteristics
- Shrink ratio: 2:1
- Very flexible, high flame retardant
- Low shrink temperature and rapid shrinkage
- Excellent physical, chemical and electrical performance
- Compliance with RoHS
Specification
- Characteristics
- Specification
- Technical Data
Part Number | Nominal Size(mm) | As supplied (mm) REF. | After recovered (mm) | Standard Length (Meter) | ||
---|---|---|---|---|---|---|
I.D. | W.T. | I.D.(max) | W.T.(min) | |||
G5-CB0010 |
1.0 |
1.4±0.2 |
0.10±0.03 |
0.7 |
0.20 |
200 |
G5-CB0015 |
1.5 |
1.9±0.2 |
0.10±0.03 |
0.8 |
0.20 |
200 |
G5-CB0020 |
2.0 |
2.4±0.2 |
0.12±0.03 |
1.0 |
0.20 |
200 |
G5-CB0025 |
2.5 |
2.8±0.3 |
0.13±0.05 |
1.25 |
0.25 |
200 |
G5-CB0030 |
3.0 |
3.4±0.3 |
0.13±0.05 |
1.5 |
0.25 |
200 |
G5-CB0035 |
3.5 |
3.9±0.3 |
0.13±0.05 |
1.75 |
0.25 |
200 |
G5-CB0040 |
4.0 |
4.4±0.3 |
0.15±0.05 |
2.0 |
0.25 |
200 |
G5-CB0045 |
4.5 |
5.0±0.3 |
0.15±0.05 |
2.25 |
0.25 |
100 |
G5-CB0050 |
5.0 |
5.5±0.3 |
0.15±0.05 |
2.5 |
0.25 |
100 |
G5-CB0060 |
6.0 |
6.5±0.3 |
0.15±0.05 |
3.0 |
0.28 |
100 |
G5-CB0070 |
7.0 |
7.5±0.3 |
0.15±0.05 |
3.5 |
0.28 |
100 |
G5-CB0080 |
8.0 |
8.6±0.4 |
0.15±0.05 |
4.0 |
0.28 |
100 |
G5-CB0090 |
9.0 |
9.6±0.4 |
0.15±0.05 |
4.5 |
0.28 |
100 |
G5-CB0100 |
10.0 |
10.6±0.4 |
0.15±0.05 |
5.0 |
0.28 |
100 |
G5-CB0110 |
11.0 |
11.6±0.4 |
0.18±0.05 |
5.5 |
0.28 |
100 |
G5-CB0120 |
12.0 |
12.6±0.4 |
0.20±0.05 |
6.0 |
0.28 |
100 |
G5-CB0130 |
13.0 |
13.6±0.4 |
0.20±0.05 |
6.5 |
0.30 |
100 |
G5-CB0140 |
14.0 |
14.6±0.4 |
0.20±0.05 |
7.0 |
0.30 |
100 |
G5-CB0150 |
15.0 |
15.6±0.5 |
0.20±0.05 |
7.5 |
0.32 |
100 |
G5-CB0160 |
16.0 |
16.6±0.5 |
0.20±0.05 |
8.0 |
0.32 |
100 |
Technical Data
Property | Specification Requirement | Test Method | Typical Value |
---|---|---|---|
Longitudinal change |
-10%~10% |
ASTM D 2671 |
Pass |
Tensile strength |
≥10.3MPa |
ASTM D 2671 |
≥11.3MPa |
Elongation at break |
≥200% |
ASTM D 2671 |
≥400% |
Tensile strength after aging |
70% of initial value |
ASTM D 2671 |
≥80% |
Elongation at break after aging |
≥100% |
ASTM D 2671 |
≥200% |
Heat shock | No cracking |
ASTM D 2671 |
No Cracking |
Low temperature flexibility | No cracking |
ASTM D 2671 |
No Cracking |
Dielectric voltage withstand | AC2500V/60S No breakdown |
ASTM D2671 |
No breakdown |
Volume resistivity | ≧1014Ω‧cm |
ASTM D 2671 |
≥1014Ω.cm |
Dielectric strength | ≧19.7KV/mm |
ASTM D2671 |
22 KV/mm |
Flammability | VW-1 |
UL224 |
Pass |